| Function: |
 |
Phase failure |
 |
Phase sequence relay 3 phase |
|
| Mounting: |
 |
DIN Rail |
|
 |
|
|
| Number of Contacts: |
 |
EWS 1 C/O |
 |
EWS2 2 C/O |
 |
8 Amp (AC1) 250 V |
|
| Monitored Voltage: |
 |
3 x 230 V AC to 3 x 440 V AC |
|
 |
|
|
|
|
|
|
 |
 |
|
 |
|
|
|
| Function: |
 |
Phase sequence and loss of phase relay |
 |
Sensitivity and time delay adjustable |
|
| Mounting: |
 |
DIN Rail |
|
 |
|
|
| Number of Contacts: |
 |
2 C/O |
 |
8 Amp (AC1) 250 V |
|
| Monitored Voltage: |
 |
3 x 415 V AC |
|
 |
|
|
|
|
|
 |
 |
|
 |
|
|
|
| Function: |
 |
Phase asymmetry, sequence and loss of phase relay |
|
| Mounting: |
 |
DIN Rail |
|
 |
|
|
| Number of Contacts: |
 |
1 C/O |
 |
8 Amp (AC1) 250 V |
|
| Monitored Voltage: |
 |
3 x 400 V AC |
|
 |
|
|
|
|
|
|
 |
|
 |
 |
|
 |
|
|
|
| Function: |
 |
Voltage threshold monitoring of own single phase supply |
 |
Selectable over voltage or under voltage control mode |
 |
Adjustable time delay |
|
| Mounting: |
 |
DIN Rail |
|
 |
|
|
|
| Number of Contacts: |
 |
1 C/O |
 |
8 Amp (AC1) 250 V |
|
| Monitored Voltage: |
 |
12 V DC |
 |
20 V - 80 V AC/DC |
 |
65 V- 260 V AC/DC |
|
 |
|
|
|
|
|
|
 |
 |
|
 |
|
|
|
| Function: |
 |
Voltage threshold monitoring of own single phase supply |
 |
Fixed hysteresis (5%) |
 |
Selectable high and low voltage thresholds |
|
| Mounting: |
 |
DIN Rail |
|
 |
|
|
|
| Number of Contacts: |
 |
1 C/O |
 |
8 Amp (AC1) 250 V |
|
| Monitored Voltage: |
 |
20 V - 80 V AC/DC |
 |
65 V- 260 V AC/DC |
|
 |
|
|
|
|
|
|
 |
 |
|
 |
|
|
|
| Function: |
 |
Voltage monitoring - single phase |
 |
Selectable overvoltage or undervoltage control mode |
 |
Adjustable time delay |
|
| Mounting: |
 |
DIN Rail |
|
 |
|
|
|
| Number of Contacts: |
 |
1 C/O |
 |
8 Amp (AC1) 250 V |
|
| Monitored Voltage: |
 |
EUL 0.2 V - 60 V AC |
 |
EUH 15 V - 600 V AC |
|
| Supply Voltage: |
 |
24 V DC |
 |
24 V AC |
 |
230 V AC |
|
 |
|
|
|
|
|
|
 |
 |
|
 |
|
|
|
| Function: |
 |
Voltage control for 3 phase network |
 |
Controls over and under voltages on own supply |
|
| Mounting: |
 |
DIN Rail |
|
 |
|
|
|
| Number of Contacts: |
 |
2 C/O |
 |
8 Amp (AC1) 250 V |
|
| Monitored Voltage: |
 |
F3US 3 phase to phase |
 |
F3USN 3 phase to neutral |
|
| Supply Voltage: |
 |
230 V AC |
 |
400 V AC |
|
 |
|
|
|
|
|
|
 |
 |
|
 |
|
|
|
| Function: |
 |
Voltage monitoring - single phase |
 |
Display of current value and preset value on LCD |
|
| Mounting: |
 |
DIN Rail |
|
 |
|
|
|
| Number of Contacts: |
 |
1 C/O |
 |
5 AMP (AC1) 250 V |
|
| Monitored Voltage: |
 |
HDU-L 0.2 V - 60 V |
 |
HDU-H 15 V - 600 V |
|
| Supply Voltage: |
 |
24 V DC |
 |
24 V AC |
 |
230 V AC |
|
 |
|
|
|
|
|
|
 |
|
 |
 |
|
 |
|
|
|
| Function: |
 |
Current monitoring 2mA to 10A AC/DC single phase |
 |
Measure up to 100 A with EITCT accessory |
|
| Mounting: |
 |
DIN Rail |
|
 |
|
 |
|
|
|
| Number of Contacts: |
 |
1 C/O |
 |
8 AMP (AC1) 250 V |
|
| Monitored Current: |
 |
EIL 2 - 500 mA |
 |
EIH 0.1 - 10A |
 |
EIT 10 - 100 A (with CT) |
|
| Supply Voltage: |
 |
24 V DC |
 |
24 V AC |
 |
230 V AC |
|
|
|
|
|
|
 |
 |
|
 |
|
|
|
| Function: |
 |
Current monitoring - single phase |
 |
Display of current value and preset value on LCD |
|
| Mounting: |
 |
DIN Rail |
|
 |
|
 |
|
|
|
| Number of Contacts: |
 |
1 C/O |
 |
5 AMP (AC1) 250 V |
|
| Monitored Current: |
 |
HDI-L 2 - 500 mA |
 |
HDI - H 0.1 - 10 A |
|
| Supply Voltage: |
 |
24 V DC |
 |
24 V AC |
 |
230 V AC |
|
|
|
|
|
|
 |
|
 |
 |
|
 |
|
|
|
| Function: |
 |
ENR - Liquid level monitoring pump up or down |
 |
ENRM - Liquid level monitoring pump up or down with adjustable time delay |
|
| Mounting: |
 |
DIN Rail |
|
 |
|
|
|
| Number of Contacts: |
 |
1 C/O |
 |
8 AMP (AC1) 250 V |
|
| Probes to Suit: |
 |
S3, S5, S7, S8 |
|
| Supply Voltage: |
 |
24 V AC |
 |
230 V AC |
|
(ENR) |
|
(ENRM) |
|
|
|
|
|
|
 |
 |
|
 |
|
|
|
| Function: |
 |
Level control with alarm |
|
| Mounting: |
 |
DIN Rail |
|
 |
|
 |
|
|
|
| Number of Contacts: |
 |
1 C/O |
 |
8 AMP (AC1) 250 V |
|
| Probes to Suit: |
 |
S3, S5, S7, S8 |
|
| Supply Voltage: |
 |
24 V AC |
 |
230 V AC |
|
|
|
|
|
|
 |
 |
|
 |
|
|
|
| Function: |
 |
Control and regulation of liquid levels |
 |
Combined regulation - emptying a well and filling a tank |
|
| Mounting: |
 |
DIN Rail |
|
 |
|
|
|
| Number of Contacts: |
 |
1 C/O |
 |
8 AMP (AC1) 250 V |
|
| Probes to Suit: |
 |
S3, S5, S7, S8 |
|
| Supply Voltage: |
 |
24 V AC |
 |
230 V AC |
|
 |
|
|
|
|
|
|
 |
|
 |
 |
|
 |
|
|
|
| Function: |
 |
Underspeed control relay |
|
| Mounting: |
 |
DIN Rail |
|
 |
|
 |
|
|
|
| Number of Contacts: |
 |
1 C/O |
 |
8 AMP (AC1) 250 V |
|
| Supply Voltage: |
 |
24 V DC |
 |
24 V AC |
 |
230 V AC |
|
|
|
|
|
|
 |
|
 |
 |
|
 |
|
|
|
| Function: |
 |
Motor load control relay |
 |
Power factor relay |
 |
Low threshold output (R1) |
 |
High threshold output (R2) |
|
| Mounting: |
 |
DIN Rail |
|
 |
|
|
|
| Number of Contacts: |
 |
1 C/O |
 |
8 AMP (AC1) 250 V |
|
| Supply Voltage: |
 |
24 V DC |
 |
24 V AC |
 |
230 V AC |
|
 |
|
|
|
|
|